Multiplex Assay Kit for Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay)

CMS1A; CMS1A2; CHOACTase; Choline acetylase

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-92 88
EDTA plasma(n=5) 86-101 91
heparin plasma(n=5) 79-88 79
sodium citrate plasma(n=5) 81-95 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 78-101% 83-94% 83-97%
EDTA plasma(n=5) 96-104% 95-103% 99-105% 90-97%
heparin plasma(n=5) 98-105% 90-103% 98-105% 90-104%
sodium citrate plasma(n=5) 82-89% 97-104% 81-98% 87-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:ChAT) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Neurochemical Research Trans-resveratrol Inhibits Tau Phosphorylation in the Brains of Control and Cadmium Chloride-Treated Rats by Activating PP2A and PI3K/Akt Induced-Inhibition of … Pubmed: 30478674
neurotoxicity research Melatonin Improves Memory Deficits in Rats with Cerebral Hypoperfusion, Possibly, Through Decreasing the Expression of Small-Conductance Ca2+-Activated K+ … Pubmed: 31187398
BMC Anesthesiology Cerebrospinal fluid cholinergic biomarkers are associated with postoperative delirium in elderly patients undergoing Total hip/knee replacement: a … Pubmed: 32988385
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPB929Mu02 Recombinant Choline Acetyltransferase (ChAT) Positive Control; Immunogen; SDS-PAGE; WB.
RPB929Mu01 Recombinant Choline Acetyltransferase (ChAT) Positive Control; Immunogen; SDS-PAGE; WB.
PAB929Mu01 Polyclonal Antibody to Choline Acetyltransferase (ChAT) WB; IHC; ICC; IP.
PAB929Mu02 Polyclonal Antibody to Choline Acetyltransferase (ChAT) WB; IHC; ICC; IP.
SEB929Mu ELISA Kit for Choline Acetyltransferase (ChAT) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB929Mu Multiplex Assay Kit for Choline Acetyltransferase (ChAT) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.