Multiplex Assay Kit for Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay)

COL4-A5; ASLN; ATS; CA54; Collagen Alpha-5(IV)chain; Alport Syndrome

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-104 96
EDTA plasma(n=5) 80-96 90
heparin plasma(n=5) 96-105 101
sodium citrate plasma(n=5) 96-105 99

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 84-98% 92-105% 94-102%
EDTA plasma(n=5) 86-94% 92-101% 81-94% 78-104%
heparin plasma(n=5) 83-91% 86-93% 87-96% 89-103%
sodium citrate plasma(n=5) 84-97% 98-105% 99-105% 90-104%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:COL4a5) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Experimental and Molecular Pathology  Epitope recognized by anti-glomerular basement membrane (GBM) antibody in a patient with repeated relapse of anti-GBM disease Pubmed: 30817909
American Journal of Respiratory Cell and Molecular Biology Basement Membrane Remodelling Controls Endothelial Function in IPAH Pubmed: 32160015
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC141Hu01 Recombinant Collagen Type IV Alpha 5 (COL4a5) Positive Control; Immunogen; SDS-PAGE; WB.
PAC141Hu01 Polyclonal Antibody to Collagen Type IV Alpha 5 (COL4a5) WB
LAC141Hu71 Biotin-Linked Polyclonal Antibody to Collagen Type IV Alpha 5 (COL4a5) WB; IHC; ICC.
MAC141Hu21 Monoclonal Antibody to Collagen Type IV Alpha 5 (COL4a5) WB; IHC; ICC; IP.
MAC141Hu22 Monoclonal Antibody to Collagen Type IV Alpha 5 (COL4a5) WB; IHC; ICC; IP.
LAC141Hu82 FITC-Linked Monoclonal Antibody to Collagen Type IV Alpha 5 (COL4a5) WB; IHC; ICC; IF.
SEC141Hu ELISA Kit for Collagen Type IV Alpha 5 (COL4a5) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC141Hu Multiplex Assay Kit for Collagen Type IV Alpha 5 (COL4a5) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.