Multiplex Assay Kit for Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay)

ATC2; CRN; Lrp4; TMPRSS10; Atrial Natriuretic Peptide-Converting Enzyme, Serine Protease; Heart-specific serine proteinase ATC2; Pro-ANP-converting enzyme

(Note: Up to 8-plex in one testing reaction)

Specificity

This assay has high sensitivity and excellent specificity for detection of Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 80-103 85
heparin plasma(n=5) 96-103 101
sodium citrate plasma(n=5) 84-95 87

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-95% 94-101% 99-105% 94-104%
EDTA plasma(n=5) 86-98% 91-98% 83-97% 80-98%
heparin plasma(n=5) 83-99% 79-90% 94-103% 91-98%
sodium citrate plasma(n=5) 99-105% 84-95% 88-96% 81-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
96-well plate 1 Plate sealer for 96 wells 4
Pre-Mixed Standard 2 Standard Diluent 1×20mL
Pre-Mixed Magnetic beads (22#:CRN) 1 Analysis buffer 1×20mL
Pre-Mixed Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B (PE-SA) 1×120μL Assay Diluent B 1×12mL
Sheath Fluid 1×10mL Wash Buffer (30 × concentrate) 1×20mL
Instruction manual 1

Assay procedure summary

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS One Enhanced heart failure, mortality and renin activation in female mice with experimental dilated cardiomyopathy pubmed:29240788
PLoS One Increases in plasma corin levels following experimental myocardial infarction reflect the severity of ischemic injury Pubmed: 30192780
American Journal of Pathology Placental overexpression of soluble CORIN in preeclampsia Pubmed: 32084366
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPG316Mu01 Recombinant Corin (CRN) Positive Control; Immunogen; SDS-PAGE; WB.
RPG316Mu02 Recombinant Corin (CRN) Positive Control; Immunogen; SDS-PAGE; WB.
PAG316Mu01 Polyclonal Antibody to Corin (CRN) WB; IHC; ICC; IP.
PAG316Mu02 Polyclonal Antibody to Corin (CRN) WB; IHC; ICC; IP.
SEG316Mu ELISA Kit for Corin (CRN) Enzyme-linked immunosorbent assay for Antigen Detection.
LMG316Mu Multiplex Assay Kit for Corin (CRN) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.