CLIA Kit for Tissue Inhibitors Of Metalloproteinase 4 (TIMP4)

TIMP Metallopeptidase Inhibitor 4; Tissue Inhibitor of Metalloproteinases 4

Specificity

This assay has high sensitivity and excellent specificity for detection of Tissue Inhibitors Of Metalloproteinase 4 (TIMP4).
No significant cross-reactivity or interference between Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) and the recovery rates were calculated by comparing the measured value to the expected amount of Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 93-101 96
EDTA plasma(n=5) 78-101 83
heparin plasma(n=5) 86-102 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-95% 99-105% 99-105% 95-102%
EDTA plasma(n=5) 84-92% 78-103% 78-97% 81-89%
heparin plasma(n=5) 78-90% 91-98% 81-92% 87-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS ONE A Combinatorial Relative Mass Value Evaluation of Endogenous Bioactive Proteins in Three-Dimensional Cultured Nucleus Pulposus Cells of Herniated Intervertebral Discs: Identification of Potential Target Proteins for Gene Therapeutic Approaches Plosone: Source
Catalog No. Related products for research use of Bos taurus; Bovine (Cattle) Organism species Applications (RESEARCH USE ONLY!)
RPA130Bo01 Recombinant Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) Positive Control; Immunogen; SDS-PAGE; WB.
PAA130Bo01 Polyclonal Antibody to Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) WB; IHC; ICC; IP.
LAA130Bo71 Biotin-Linked Polyclonal Antibody to Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) WB; IHC; ICC.
MAA130Bo21 Monoclonal Antibody to Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) WB; IHC; ICC; IP.
SEA130Bo ELISA Kit for Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA130Bo CLIA Kit for Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) Chemiluminescent immunoassay for Antigen Detection.
LMA130Bo Multiplex Assay Kit for Tissue Inhibitors Of Metalloproteinase 4 (TIMP4) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.