ELISA Kit for Cadherin, Epithelial (CDHE)

CD324; CDH1; Arc1; ECAD; CDH-E; E-CAD; LCAM; UVO; Cadherin 1 Type 1; Uvomorulin; E-Cadherin; Calcium-Dependent Adhesion Protein, Epithelial; Liver Cell Adhesion Molecule

Specificity

This assay has high sensitivity and excellent specificity for detection of Cadherin, Epithelial (CDHE).
No significant cross-reactivity or interference between Cadherin, Epithelial (CDHE) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cadherin, Epithelial (CDHE) and the recovery rates were calculated by comparing the measured value to the expected amount of Cadherin, Epithelial (CDHE) in samples.

MatrixRecovery range (%)Average(%)
serum(n=5)97-104101
EDTA plasma(n=5)88-10597
heparin plasma(n=5)89-9693

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cadherin, Epithelial (CDHE) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cadherin, Epithelial (CDHE) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cadherin, Epithelial (CDHE) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample1:21:41:81:16
serum(n=5)92-105%78-96%80-101%96-104%
EDTA plasma(n=5)88-104%82-102%78-96%80-92%
heparin plasma(n=5)81-92%87-96%98-105%95-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

ReagentsQuantityReagentsQuantity
Pre-coated, ready to use 96-well strip plate1Plate sealer for 96 wells4
Standard2Standard Diluent1×20mL
Detection Reagent A1×120µLAssay Diluent A1×12mL
Detection Reagent B1×120µLAssay Diluent B1×12mL
TMB Substrate1×9mLStop Solution1×6mL
Wash Buffer (30 × concentrate)1×20mLInstruction manual1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

MagazineReference
J Periodontal Res.Novel method for proliferation of oral keratinocyte stem cellsPubmed: 24329011
Catalog No.Related products for research use of Homo sapiens (Human) Organism speciesApplications
RPA017Hu01Recombinant Cadherin, Epithelial (CDHE)Positive Control; Immunogen; SDS-PAGE; WB.
PAA017Hu01Polyclonal Antibody to Cadherin, Epithelial (CDHE)WB; IHC; ICC; IP.
PAA017Hu02Polyclonal Antibody to Cadherin, Epithelial (CDHE)WB; IHC; ICC; IP.
LAA017Hu71Biotin-Linked Polyclonal Antibody to Cadherin, Epithelial (CDHE)WB; IHC; ICC.
LAA017Hu81FITC-Linked Polyclonal Antibody to Cadherin, Epithelial (CDHE)WB; IHC; ICC; IF.
MAA017Hu22Monoclonal Antibody to Cadherin, Epithelial (CDHE)WB; IHC; ICC; IP.
SEA017HuELISA Kit for Cadherin, Epithelial (CDHE)Enzyme-linked immunosorbent assay for Antigen Detection.
SCA017HuCLIA Kit for Cadherin, Epithelial (CDHE)Chemiluminescent immunoassay for Antigen Detection.