• Featured-Product
ELISA Kit for Cluster Of Differentiation 23 (CD23)

FceRII; FCER2; BLAST-2; CLEC4J; FCE2; IGEBF; Receptor II For The Fc Region Of Immunoglobulin E; C-type lectin domain family 4 member J; Immunoglobulin E-binding factor; Lymphocyte IgE receptor

Specificity

This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 23 (CD23).
No significant cross-reactivity or interference between Cluster Of Differentiation 23 (CD23) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Cluster Of Differentiation 23 (CD23) and the recovery rates were calculated by comparing the measured value to the expected amount of Cluster Of Differentiation 23 (CD23) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-93 89
EDTA plasma(n=5) 83-96 90
heparin plasma(n=5) 89-104 95

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 23 (CD23) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 23 (CD23) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cluster Of Differentiation 23 (CD23) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 80-102% 79-95% 89-103%
EDTA plasma(n=5) 83-92% 91-105% 91-105% 79-103%
heparin plasma(n=5) 82-98% 88-104% 96-105% 82-93%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPB582Hu01 Recombinant Cluster Of Differentiation 23 (CD23) Positive Control; Immunogen; SDS-PAGE; WB.
APB582Hu01 Active Cluster Of Differentiation 23 (CD23) Cell culture; Activity Assays.
APB582Hu61 Active Cluster Of Differentiation 23 (CD23) Cell culture; Activity Assays.
EPB582Hu61 Eukaryotic Cluster Of Differentiation 23 (CD23) Positive Control; Immunogen; SDS-PAGE; WB.
PAB582Hu01 Polyclonal Antibody to Cluster Of Differentiation 23 (CD23) WB; IHC
MAB582Hu22 Monoclonal Antibody to Cluster Of Differentiation 23 (CD23) WB; IHC; ICC; IP.
MAB582Hu26 Monoclonal Antibody to Cluster Of Differentiation 23 (CD23) WB; IHC; ICC; IP.
MAB582Hu21 Monoclonal Antibody to Cluster Of Differentiation 23 (CD23) WB; IHC
FAB582Hu02 Anti-Cluster Of Differentiation 23 (CD23) Monoclonal Antibody F
FAB582Hu04 Anti-Cluster Of Differentiation 23 (CD23) Monoclonal Antibody Flow cytometry.
FAB582Hu06 Anti-Cluster Of Differentiation 23 (CD23) Monoclonal Antibody Flow cytometry.
FAB582Hu86 FITC-Linked Anti-Cluster Of Differentiation 23 (CD23) Monoclonal Antibody FCM
FAB582Hu82 FITC-Linked Anti-Cluster Of Differentiation 23 (CD23) Monoclonal Antibody FCM
SEB582Hu ELISA Kit for Cluster Of Differentiation 23 (CD23) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB582Hu Multiplex Assay Kit for Cluster Of Differentiation 23 (CD23) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.