ELISA Kit for Methionine Sulfoxide Reductase A (MSRA)

PMSR; Peptide Methionine Sulfoxide Reductase; Protein-methionine-S-oxide reductase

Specificity

This assay has high sensitivity and excellent specificity for detection of Methionine Sulfoxide Reductase A (MSRA).
No significant cross-reactivity or interference between Methionine Sulfoxide Reductase A (MSRA) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Methionine Sulfoxide Reductase A (MSRA) and the recovery rates were calculated by comparing the measured value to the expected amount of Methionine Sulfoxide Reductase A (MSRA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-98 94
EDTA plasma(n=5) 88-97 93
heparin plasma(n=5) 93-105 97

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Methionine Sulfoxide Reductase A (MSRA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Methionine Sulfoxide Reductase A (MSRA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Methionine Sulfoxide Reductase A (MSRA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-97% 92-103% 99-105% 79-90%
EDTA plasma(n=5) 89-103% 80-89% 79-99% 91-98%
heparin plasma(n=5) 92-104% 82-99% 78-89% 83-98%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Chem Biol Interact Dysfunction of methionine sulfoxide reductases to repair damaged proteins by nickel nanoparticles PubMed: 25979628
Scientific Reports Protein oxidation and degradation caused by particulate matter. pubmed:27644844
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC629Hu01 Recombinant Methionine Sulfoxide Reductase A (MSRA) Positive Control; Immunogen; SDS-PAGE; WB.
PAC629Hu01 Polyclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB,IHC,ICC/IF
MAC629Hu21 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu22 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC
MAC629Hu23 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu24 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu25 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
MAC629Hu27 Monoclonal Antibody to Methionine Sulfoxide Reductase A (MSRA) WB; IHC; ICC; IP.
SEC629Hu ELISA Kit for Methionine Sulfoxide Reductase A (MSRA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC629Hu Multiplex Assay Kit for Methionine Sulfoxide Reductase A (MSRA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PGC629Hu01 Primer Pair for Methionine Sulfoxide Reductase A (MSRA) PCR