ELISA Kit for Peptidylglycine Alpha Amidating Monooxygenase (PAM)

PAL; PHM; Peptidylamidoglycolate lyase; Peptidyl-Alpha-hydroxyglycine Alpha-amidating Lyase; Peptidylglycine Alpha-Hydroxylating Monooxygenase

Specificity

This assay has high sensitivity and excellent specificity for detection of Peptidylglycine Alpha Amidating Monooxygenase (PAM).
No significant cross-reactivity or interference between Peptidylglycine Alpha Amidating Monooxygenase (PAM) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Peptidylglycine Alpha Amidating Monooxygenase (PAM) and the recovery rates were calculated by comparing the measured value to the expected amount of Peptidylglycine Alpha Amidating Monooxygenase (PAM) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 97-105 101
EDTA plasma(n=5) 86-96 93
heparin plasma(n=5) 87-95 90

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Peptidylglycine Alpha Amidating Monooxygenase (PAM) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Peptidylglycine Alpha Amidating Monooxygenase (PAM) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Peptidylglycine Alpha Amidating Monooxygenase (PAM) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 96-105% 82-89% 82-96% 88-98%
EDTA plasma(n=5) 90-105% 90-97% 87-101% 84-91%
heparin plasma(n=5) 89-101% 91-105% 80-93% 87-103%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APC744Hu01 Active Peptidylglycine Alpha Amidating Monooxygenase (PAM) Cell culture; Activity Assays.
EPC744Hu61 Eukaryotic Peptidylglycine Alpha Amidating Monooxygenase (PAM) Positive Control; Immunogen; SDS-PAGE; WB.
RPC744Hu01 Recombinant Peptidylglycine Alpha Amidating Monooxygenase (PAM) Positive Control; Immunogen; SDS-PAGE; WB.
PAC744Hu01 Polyclonal Antibody to Peptidylglycine Alpha Amidating Monooxygenase (PAM) WB; IHC; ICC; IP.
MAC744Hu22 Monoclonal Antibody to Peptidylglycine Alpha Amidating Monooxygenase (PAM) WB; IHC; ICC; IP.
SEC744Hu ELISA Kit for Peptidylglycine Alpha Amidating Monooxygenase (PAM) Enzyme-linked immunosorbent assay for Antigen Detection.