ELISA Kit for Ribonuclease A2 (RNASE2)

Rnase-A2; Rnase2; EDN; Ribonuclease US; Ribonuclease,RNase A Family,2; Liver,Eosinophil-Derived Neurotoxin; MNon-secretory ribonuclease

Specificity

This assay has high sensitivity and excellent specificity for detection of Ribonuclease A2 (RNASE2).
No significant cross-reactivity or interference between Ribonuclease A2 (RNASE2) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ribonuclease A2 (RNASE2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ribonuclease A2 (RNASE2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
PLoS One Elevation of Eosinophil-Derived Neurotoxin in Plasma of the Subjects with Aspirin-Exacerbated Respiratory Disease: A Possible Peripheral Blood Protein Biomarker PubMed: PMC3689668
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPD169Hu01 Recombinant Ribonuclease A2 (RNASE2) Positive Control; Immunogen; SDS-PAGE; WB.
CPD169Hu21 OVA Conjugated Ribonuclease A2 (RNASE2) Immunogen; SDS-PAGE; WB.
PAD169Hu01 Polyclonal Antibody to Ribonuclease A2 (RNASE2) WB,IHC
MAD169Hu21 Monoclonal Antibody to Ribonuclease A2 (RNASE2) WB; IHC
MAD169Hu25 Monoclonal Antibody to Ribonuclease A2 (RNASE2) WB; IHC; ICC; IP.
MAD169Hu29 Monoclonal Antibody to Ribonuclease A2 (RNASE2) WB; IHC; ICC; IP.
MAD169Hu22 Monoclonal Antibody to Ribonuclease A2 (RNASE2) WB; IHC; ICC; IP.
MAD169Hu24 Monoclonal Antibody to Ribonuclease A2 (RNASE2) WB; IHC; ICC; IP.
MAD169Hu27 Monoclonal Antibody to Ribonuclease A2 (RNASE2) WB; IHC; ICC; IP.
MAD169Hu23 Monoclonal Antibody to Ribonuclease A2 (RNASE2) WB; IHC
SED169Hu ELISA Kit for Ribonuclease A2 (RNASE2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD169Hu Multiplex Assay Kit for Ribonuclease A2 (RNASE2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PGD169Hu01 Primer Pair for Ribonuclease A2 (RNASE2) PCR