ELISA Kit for Glucagon Like Peptide 1 Receptor (GLP1R)

Specificity

This assay has high sensitivity and excellent specificity for detection of Glucagon Like Peptide 1 Receptor (GLP1R).
No significant cross-reactivity or interference between Glucagon Like Peptide 1 Receptor (GLP1R) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glucagon Like Peptide 1 Receptor (GLP1R) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glucagon Like Peptide 1 Receptor (GLP1R) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
American Journal of Translational Research Subcutaneous liraglutide ameliorates methylglyoxal-induced Alzheimer-like tau pathology and cognitive impairment by modulating tau hyperphosphorylation and glycogen synthase kinase-3β. pubmed:28337257
International Journal of Medical Sciences Blockade of Central GLP-1 Receptors Deteriorates the Improvement of Diabetes after IlealTransposition. pubmed:27994501
Nutrients The Glucose-Lowering Effect of Foxtail Millet in Subjects with Impaired Glucose Tolerance: A Self-Controlled Clinical Trial Pubmed: 30326632
Catalog No. Related products for research use of Mus musculus (Mouse) Organism species Applications (RESEARCH USE ONLY!)
RPD475Mu02 Recombinant Glucagon Like Peptide 1 Receptor (GLP1R) Positive Control; Immunogen; SDS-PAGE; WB.
RPD475Mu01 Recombinant Glucagon Like Peptide 1 Receptor (GLP1R) Positive Control; Immunogen; SDS-PAGE; WB.
PAD475Mu01 Polyclonal Antibody to Glucagon Like Peptide 1 Receptor (GLP1R) WB; IHC; ICC; IP.
PAD475Mu02 Polyclonal Antibody to Glucagon Like Peptide 1 Receptor (GLP1R) WB; IHC; ICC; IP.
SED475Mu ELISA Kit for Glucagon Like Peptide 1 Receptor (GLP1R) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD475Mu Multiplex Assay Kit for Glucagon Like Peptide 1 Receptor (GLP1R) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.