ELISA Kit for Ecotin (ECO)

Specificity

This assay has high sensitivity and excellent specificity for detection of Ecotin (ECO).
No significant cross-reactivity or interference between Ecotin (ECO) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ecotin (ECO) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ecotin (ECO) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
The Journal of Immunology Blocking Fcα receptor I on granulocytes prevents tissue damage induced by IgA autoantibodies. PubMed: 22802416
PLOS ONE CD98 Positive Eosinophils Contribute to T Helper 1 Pattern Inflammation PlosOne: Source
Inflammation Research Inhibitory effect of baicalin on allergic response in ovalbumin-induced allergic rhinitis guinea pigs and lipopolysaccharide-stimulated human mast cells pubmed:27043920
PLoS Neglected Tropical Diseases Functional and phenotypic evaluation of eosinophils from patients with the acute form of paracoccidioidomycosis pubmed:28489854
Catalog No. Related products for research use of Pan-species (General) Organism species Applications (RESEARCH USE ONLY!)
RPX655Ge01 Recombinant Ecotin (ECO) Positive Control; Immunogen; SDS-PAGE; WB.
PAX655Ge01 Polyclonal Antibody to Ecotin (ECO) WB; IHC; ICC; IP.
LAX655Ge71 Biotin-Linked Polyclonal Antibody to Ecotin (ECO) WB; IHC; ICC.
SEX655Ge ELISA Kit for Ecotin (ECO) Enzyme-linked immunosorbent assay for Antigen Detection.
HEX655Ge High Sensitive ELISA Kit for Ecotin (ECO) Enzyme-linked immunosorbent assay for Antigen Detection.
LMX655Ge Multiplex Assay Kit for Ecotin (ECO) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSX655Ge01 ELISA Kit DIY Materials for Ecotin (ECO) Main materials for "Do It (ELISA Kit) Yourself".