CLIA Kit for Meningioma Expressed Antigen 5 (MGEA5)

NAGase; MEA5; NCOAT; Hexosaminidase C; N-Acetylhexosaminidase; Hyaluronidase; Meningioma-Expressed Antigen 5; Nuclear Cytoplasmic O-GlcNAcase And Acetyltransferase

Specificity

This assay has high sensitivity and excellent specificity for detection of Meningioma Expressed Antigen 5 (MGEA5).
No significant cross-reactivity or interference between Meningioma Expressed Antigen 5 (MGEA5) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Meningioma Expressed Antigen 5 (MGEA5) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Meningioma Expressed Antigen 5 (MGEA5) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Plos one Metal-on-Metal Hip Prostheses and Systemic Health: A Cross-Sectional Association Study 8 Years after Implantation PubMed: PMC3677913
Renal Failure Evaluation of the Process of Recycling and Renal Parenchymal Injury after ESWL with Metabolites Excreted in the Urine Pubmed: 23413820
BioMed Research International The Renal Effects of Vanadate Exposure: Potential Biomarkers and Oxidative Stress as a Mechanism of Functional Renal Disorders—Preliminary Studies Hindawi: 740105
PLoS One Ameliorative Effect of Chrysin on Adenine-Induced Chronic Kidney Disease in Rats PubMed: 25909514
Ecotoxicol Environ Saf Melamine and oxalate coexposure induces early kidney tubular injury through mitochondrial aberrations and oxidative stress 34507040
Antioxidants Diminishment of Nrf2 Antioxidative Defense Aggravates Nephrotoxicity of Melamine and Oxalate Coexposure. Antioxidants 2021, 10, 1464 34573096
Catalog No. Related products for research use of Rattus norvegicus (Rat) Organism species Applications (RESEARCH USE ONLY!)
RPA069Ra02 Recombinant Meningioma Expressed Antigen 5 (MGEA5) Positive Control; Immunogen; SDS-PAGE; WB.
RPA069Ra01 Recombinant Meningioma Expressed Antigen 5 (MGEA5) Positive Control; Immunogen; SDS-PAGE; WB.
PAA069Ra01 Polyclonal Antibody to Meningioma Expressed Antigen 5 (MGEA5) WB; IHC; ICC; IP.
PAA069Ra02 Polyclonal Antibody to Meningioma Expressed Antigen 5 (MGEA5) WB; IHC; ICC; IP.
LAA069Ra71 Biotin-Linked Polyclonal Antibody to Meningioma Expressed Antigen 5 (MGEA5) WB; IHC; ICC.
SEA069Ra ELISA Kit for Meningioma Expressed Antigen 5 (MGEA5) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA069Ra CLIA Kit for Meningioma Expressed Antigen 5 (MGEA5) Chemiluminescent immunoassay for Antigen Detection.
LMA069Ra Multiplex Assay Kit for Meningioma Expressed Antigen 5 (MGEA5) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.