CLIA Kit for Monocyte Chemotactic Protein 3 (MCP3)

CCL7; FIC; MARC; NC28; MCP3; SCYA7; Chemokine C-C-Motif Ligand 7; Small Inducible Cytokine A7; Monocyte Chemoattractant Protein 3

Specificity

This assay has high sensitivity and excellent specificity for detection of Monocyte Chemotactic Protein 3 (MCP3).
No significant cross-reactivity or interference between Monocyte Chemotactic Protein 3 (MCP3) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Monocyte Chemotactic Protein 3 (MCP3) and the recovery rates were calculated by comparing the measured value to the expected amount of Monocyte Chemotactic Protein 3 (MCP3) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-93 90
EDTA plasma(n=5) 84-104 98
heparin plasma(n=5) 97-104 101

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Monocyte Chemotactic Protein 3 (MCP3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Monocyte Chemotactic Protein 3 (MCP3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-104% 79-92% 84-91% 78-95%
EDTA plasma(n=5) 78-103% 84-96% 91-105% 81-90%
heparin plasma(n=5) 84-98% 95-104% 79-88% 95-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
Journal of Periodontal Research Effect of omega 3 fatty acids plus low-dose aspirin on both clinical and biochemical profiles of patients with chronic periodontitis and type 2 diabetes: a randomized double blind placebo-controlled study Pubmed:25604769
Journal of Histochmistry and Cytochmistry Epigallocatechin-3-Gallate Attenuates Unilateral Ureteral Obstruction-Induced Renal Interstitial Fibrosis in Mice PubMed: 25549657
Cell Physiol Biochem MicroRNA-155 Promotes Atherosclerosis Inflammation via Targeting SOCS1 PubMed: 26159489
Cell Transplantation Ex vivo Pretreatment of Islets with Mitomycin C: Reduction in Immunogenic Potential of Islets by Suppressing Secretion of Multiple Chemotactic Factors. pubmed:28901184
NPG Asia Materials Molybdenum disulfide/graphene oxide nanocomposites show favorable lung targeting and enhanced drug loading/tumor-killing efficacy with improved … Articles:am2017225
FASEB Journal Immunomodulation by adoptive regulatory T-cell transfer improves Coxsackievirus B3-induced myocarditis Pubmed:29863913
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APA089Hu01 Active Monocyte Chemotactic Protein 3 (MCP3) Cell culture; Activity Assays.
RPA089Hu01 Recombinant Monocyte Chemotactic Protein 3 (MCP3) Positive Control; Immunogen; SDS-PAGE; WB.
PAA089Hu01 Polyclonal Antibody to Monocyte Chemotactic Protein 3 (MCP3) WB
MAA089Hu22 Monoclonal Antibody to Monocyte Chemotactic Protein 3 (MCP3) WB; IHC; ICC; IP.
SEA089Hu ELISA Kit for Monocyte Chemotactic Protein 3 (MCP3) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA089Hu CLIA Kit for Monocyte Chemotactic Protein 3 (MCP3) Chemiluminescent immunoassay for Antigen Detection.
LMA089Hu Multiplex Assay Kit for Monocyte Chemotactic Protein 3 (MCP3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA089Hu01 ELISA Kit DIY Materials for Monocyte Chemotactic Protein 3 (MCP3) Main materials for "Do It(ELISA Kit) Yourself"