CLIA Kit for Chemokine C-C-Motif Ligand 14 (CCL14)

SCYA14; HCC-1; HCC-3; NCC-2; SCYL2; CKb1; MCIF; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 14

Specificity

This assay has high sensitivity and excellent specificity for detection of Chemokine C-C-Motif Ligand 14 (CCL14).
No significant cross-reactivity or interference between Chemokine C-C-Motif Ligand 14 (CCL14) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Chemokine C-C-Motif Ligand 14 (CCL14) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine C-C-Motif Ligand 14 (CCL14) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-101 86
EDTA plasma(n=5) 81-103 88
heparin plasma(n=5) 78-88 81

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-C-Motif Ligand 14 (CCL14) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-C-Motif Ligand 14 (CCL14) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine C-C-Motif Ligand 14 (CCL14) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-103% 84-101% 88-96% 93-101%
EDTA plasma(n=5) 84-91% 88-96% 85-99% 91-103%
heparin plasma(n=5) 93-101% 78-103% 87-95% 92-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
Substrate A 1×10mL Substrate B 1×2mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

GIVEAWAYS

INCREMENT SERVICES

Magazine Citations
INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE Possible Anti-inflammatory Effects of Mesenchymal Stem Cells Transplantation via Changes in CXCL8 Levels in Patients with Refractory Rheumatoid Arthritis
Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
APB122Hu01 Active Chemokine C-C-Motif Ligand 14 (CCL14) Cell culture; Activity Assays.
RPB122Hu01 Recombinant Chemokine C-C-Motif Ligand 14 (CCL14) Positive Control; Immunogen; SDS-PAGE; WB.
RPB122Hu02 Recombinant Chemokine C-C-Motif Ligand 14 (CCL14) Positive Control; Immunogen; SDS-PAGE; WB.
PAB122Hu01 Polyclonal Antibody to Chemokine C-C-Motif Ligand 14 (CCL14) WB; IHC; ICC; IP.
PAB122Hu02 Polyclonal Antibody to Chemokine C-C-Motif Ligand 14 (CCL14) WB; IHC; ICC; IP.
LAB122Hu71 Biotin-Linked Polyclonal Antibody to Chemokine C-C-Motif Ligand 14 (CCL14) WB; IHC; ICC.
MAB122Hu22 Monoclonal Antibody to Chemokine C-C-Motif Ligand 14 (CCL14) WB; IHC; ICC; IP.
SEB122Hu ELISA Kit for Chemokine C-C-Motif Ligand 14 (CCL14) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB122Hu CLIA Kit for Chemokine C-C-Motif Ligand 14 (CCL14) Chemiluminescent immunoassay for Antigen Detection.
LMB122Hu Multiplex Assay Kit for Chemokine C-C-Motif Ligand 14 (CCL14) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.