ELISA Kit for Left/Right Determination Factor 1 (LEFTY1)

LEFTY-B; LEFTYB; LEFT-B; LEFTB; Left Right Determination Factor B

Specificity

This assay has high sensitivity and excellent specificity for detection of Left/Right Determination Factor 1 (LEFTY1).
No significant cross-reactivity or interference between Left/Right Determination Factor 1 (LEFTY1) and analogues was observed.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Left/Right Determination Factor 1 (LEFTY1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Left/Right Determination Factor 1 (LEFTY1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120µL Assay Diluent A 1×12mL
Detection Reagent B 1×120µL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

GIVEAWAYS

INCREMENT SERVICES

Catalog No. Related products for research use of Homo sapiens (Human) Organism species Applications (RESEARCH USE ONLY!)
RPC175Hu02 Recombinant Left/Right Determination Factor 1 (LEFTY1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC175Hu01 Recombinant Left/Right Determination Factor 1 (LEFTY1) Positive Control; Immunogen; SDS-PAGE; WB.
RPC175Hu03 Recombinant Left/Right Determination Factor 1 (LEFTY1) Positive Control; Immunogen; SDS-PAGE; WB.
PAC175Hu01 Polyclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
PAC175Hu03 Polyclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
PAC175Hu02 Polyclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
MAC175Hu21 Monoclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
MAC175Hu22 Monoclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC; IP.
LAC175Hu72 Biotin-Linked Monoclonal Antibody to Left/Right Determination Factor 1 (LEFTY1) WB; IHC; ICC.
SEC175Hu ELISA Kit for Left/Right Determination Factor 1 (LEFTY1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCC175Hu CLIA Kit for Left/Right Determination Factor 1 (LEFTY1) Chemiluminescent immunoassay for Antigen Detection.
LMC175Hu Multiplex Assay Kit for Left/Right Determination Factor 1 (LEFTY1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSC175Hu01 Antibody Pair for Left/Right Determination Factor 1 (LEFTY1) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSC175Hu01 ELISA Kit DIY Materials for Left/Right Determination Factor 1 (LEFTY1) Main materials for "Do It (ELISA Kit) Yourself".